2013年11月25日星期一

Setup Port Channel on Cisco 3560

I have 2 Layer3 switches. (Cisco WS-C3560X-24P-L). I am setting:

interface FastEthernet0/1
 channel-group 1 mode on
!
interface FastEthernet0/2
 channel-group 1 mode on
!
interface FastEthernet0/3
 channel-group 1 mode on
!
interface FastEthernet0/4
 channel-group 1 mode on
!
interface Port-channel 1
 no switchport
 ip address 192.168.1.2 255.255.255.0

Other switch is same but using 192.168.1.1 255.255.255.0

I am getting connectivity. But Basically would like to have fail-over and load balancing.

So out of the 4 fast Ethernet ports. If one fails. There should still be connectivity.

Get rid of your IP addresses.  Port bonding is a layer 2 game and you don't need them.

Here is an example of a working LACP etherchannel configuration on a WS-C3560G-24TS running IPservices 12.2(50)SE4.  The config on the partner switch is identical.

port-channel load-balance src-dst-mac
!
interface Port-channel23
 description ** LACP channel to SWITCH2, ports 23-24 **
 switchport trunk encapsulation dot1q
 switchport trunk native vlan 11
 switchport trunk allowed vlan 2-499
 switchport mode trunk
 switchport nonegotiate
 spanning-tree link-type point-to-point
!
interface GigabitEthernet0/23
 description ** SWITCH2 etherchannel port 1 **
 switchport trunk encapsulation dot1q
 switchport trunk native vlan 11
 switchport trunk allowed vlan 2-499
 switchport mode trunk
 switchport nonegotiate
 logging event status
 channel-group 23 mode active
!
interface GigabitEthernet0/24
 description ** SWITCH2 WS-C3560V2-48PS-S etherchannel port 2 **
 switchport trunk encapsulation dot1q
 switchport trunk native vlan 11
 switchport trunk allowed vlan 2-499
 switchport mode trunk
 switchport nonegotiate
 logging event status

 channel-group 23 mode active

2013年11月14日星期四

Cisco 3560 Switches Installing SFP Modules

Removing and installing an SFP module WS-C3560V2-48TS-S can shorten its useful life. Do not remove and insert SFP
modules more often than is absolutely necessary.
Step 1 Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface on the chassis.
Step 2 Find the send (TX) and receive (RX) markings that identify the top side of the SFP module.
Note On some SFP modules, the send and receive (TX and RX) markings might be replaced by arrows
that show the direction of the connection, either send or receive (TX or RX).
Step 3 Align the SFP module in front of the slot opening.
Step 4 Insert the SFP module into the slot until you feel the connector on the module snap into place in the rear
of the slot.
Step 5 For fiber-optic SFP modules, remove the dust plugs from the optical ports, and store them for later use.
Caution Do not remove the dust plugs from the fiber-optic SFP module port or the rubber caps from the
fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the SFP module
ports and cables from contamination and ambient light.
Step 6 Insert the cable connector into the SFP module:
 • For fiber-optic SFP modules, insert the LC or MT-RJ cable connector into the SFP module.
 • For copper SFP modules, insert the RJ-45 cable connector into the SFP module.
Note When connecting to 1000BASE-T SFP modules, be sure to use a twisted four-pair, Category 5 cable.

For more Cisco WS-C3560X-24P-L information please click here

2013年11月13日星期三

3560 Showing Garbage in Console

Cisco WS-C3560X-48PF-S  series products have two main categories, Cisco 3560V2 and Cisco 3560X, 3560V2 is FE based switch while 3560X is GE based switch, the previous Cisco 3560, 3560G and 3560E are end of sales now and replaced by Cisco 3560V2 and Cisco 3560X. Cisco Catalyst 3560 v2 Series consumes less power than its predecessors. The 3560-X Series Switches is an enterprise-class lines of stackable and standalone switches.

I have few 8-port 3560's (WS-C3560-8PC) that I have been using to roll out a Metro Ethernet upgrade.  I have one switch that originally configured just fine, but now it is displaying all kinds of gibberish in the console window.  I can telnet into the switch ok.  The configuration register on it is set to 0xF.  But I have tried using a serial connection from multiple computers, and they all show the same garbage.  I have 4 of these switches next to each other.  They all have the same IOS: 15.0(2)SE image.  They all have the same configuration register.  I can console into all of them except for this one switch.
I have verified my terminal settings, and they are as suggested:
Speed: 9600 bps     
Databits: 8      
Parity bits: 0     
Stop bit: 1     
No flow control

This time, I have tried changing to all of the following baud rates, and they all produce gibberish:
1200 bps     
2400 bps     
4800 bps     
9600 bps     
19200 bps  
38400 bps     
57600 bps     
115200 bps

3Anetwork.com keeps regular stock of 3560V2 and 3560X switches. Among all Cisco Catalyst 3560 switches, WS-C3560V2-24TS-S, WS-C3560V2-24PS-S WS-C3560X-24T-L, WS-C3560X-24T-S and WS-C3560X-24P-S are best selling models. 3Anetwork.com offers best Cisco 3560 Price, Cisco 3560V2 Price, Cisco 3560X Price, ship to worldwide.


For more Cisco WS-C3560X-48PF-L information please click here

2013年11月6日星期三

Cisco Catalyst WS-C3750V2-48PS-S Switch

An ideal fit for midsized organizations and enterprise branch offices, the Cisco WS-C3750V2-48PS-S eases deployment of converged applications and adapts to changing business needs by providing configuration flexibility and support for converged network patterns.

The Cisco Catalyst 3750V2-48PS switch not only consumes far less power than most other Cisco switches, but it also helps increase the overall productivity of your network for data, voice and video. Supporting Cisco's EnergyWise technology, this switch from Cisco's Catalyst 3750 series gives you the opportunity to manage your power consumption, reduce your overall energy costs and decrease the size of your carbon footprint.

48 x 10/100/1000 ports
Optional four Gigabit Ethernet (GbE) SFP or two 10GbE SFP+ uplink network modules
Dual redundant, modular power supplies and fans
Media Access Control Security (MACsec) hardware-based encryption
IPv4 and IPv6 routing, Multicast routing, advanced quality of service (QoS), and security features in hardware
Enhanced limited lifetime warranty (LLW) with next business day (NBD) advance hardware replacement and 90 day access to Cisco Technical Assistance Center (TAC) support
Enhanced Cisco EnergyWise for operational cost optimization by measuring actual power consumption of the device, reporting, and reducing energy consumption across the network
Cisco StackPower technology: An innovative feature and industry first for sharing power among stack members
Cisco StackWise Plus technology for ease of use and resiliency with 64 Gbps of throughput



For more Cisco WS-C3560X-24T-L information please click here


2013年10月29日星期二

How to configure Gigabit Ethernet Interfaces on Cisco 2911 Router?

Cisco 2900 Series Integrated Services Routers (ISR) have modular design that allows for reuse of a broad array of existing modules that meet business requirements while maximizing investment protection. Among all Cisco 2900 routers, Cisco2911-SEC, C2951-VSEC and C2921-VSEC are best selling models.
      
Router(config)# interface gigabitethernet 0/1
Router(config-if)#
Enters the configuration mode for a Gigabit Ethernet interface on the router.
ip address ip-address mask
Router(config-if)# ip address 192.168.12.2 255.255.255.0
Router(config-if)#
Sets the IP address and subnet mask for the specified GE interface.
no shutdown
Example:
Router(config-if)# no shutdown
Router(config-if)#
Enables the GE interface, changing its state from administratively down to administratively up.
exit
Router(config-if)# exit
Router(config)#
Exits configuration mode for the GE interface and returns to global configuration mode.

For more C2911-VSEC information please click here


2013年10月28日星期一

How to configure Settings for All RADIUS Servers on Cisco 3750x Switch?

The 3750-X Series Switches are enterprise-class lines of stackable and standalone switches with StackWise Plus technology, they are the replacement of Cisco 3750G and 3750E switches. 3Anetworkcom keeps many stocks for 3750V2 and 3750X switches. Among all Cisco Catalyst 3750 switches, WS-C3750X-12S-S and WS-C3750V2-48PS-S are best selling models.
      
configure terminal

Enter global configuration mode.

radius-server key string

Specify the shared secret text string used between the switch and all RADIUS servers.

Note       The key is a text string that must match the encryption key used on the RADIUS server. Leading spaces are ignored, but spaces within and at the end of the key are used. If you use spaces in your key, do not enclose the key in quotation marks unless the quotation marks are part of the key.


radius-server retransmit retries

Specify the number of times the switch sends each RADIUS request to the server before giving up. The default is 3; the range 1 to 1000.

radius-server timeout seconds

Specify the number of seconds a switch waits for a reply to a RADIUS request before resending the request. The default is 5 seconds; the range is 1 to 1000.

radius-server deadtime minutes

Specify the number of minutes a RADIUS server, which is not responding to authentication requests, to be skipped, thus avoiding the wait for the request to timeout before trying the next configured server. The default is 0; the range is 1 to 1440 minutes.

end

Return to privileged EXEC mode.

show running-config

Verify your settings.

copy running-config startup-config

(Optional) Save your entries in the configuration file.


For more Cisco information please click here:
http://www.3anetwork.com/cisco-ws-c3750v2-24ps-s-price_p109.html


How to configure Cisco IOS Software on Cisco WS-C3560V2-24PS-S switch?

How to configure Cisco IOS Software on Cisco WS-C3560V2-24PS-S switch?

3560V2 24 10/100 PoE + 2 SFP + IPB (Standard) Image

The Cisco Catalyst 3560 v2 Series is the next-generation energy-efficient Layer 3 fast Ethernet switches. This new series of switches supports Cisco EnergyWise technology, which enables companies to measure and manage power consumption of network infrastructure and network-attached devices, thereby reducing their energy costs and their carbon footprint. The Cisco Catalyst 3560 v2 Series consumes less power than its predecessors and is the ideal access layer switch for enterprise, retail, and branch-office environments, as it maximizes productivity and investment protection by enabling a unified network for data, voice, and video.

The Cisco Catalyst 3560 v2 Series can be preconfigured with a specific Cisco IOS Software release at the time of ordering. This option eliminates the need to reload a specific Cisco IOS Software release during deployment, thereby reducing deployment time and cost. The Cisco IOS Software release to be preloaded can be selected from a list of supported Cisco IOS Software releases, including the crypto version.

For more Cisco information please visit:
http://www.3anetwork.com/cisco-ws-c3560v2-48ps-s-price_p55.html