2014年2月18日星期二
3900 ios gateway Software MTP
I
currently have 3 Cisco 3925E call manager clusters.
Cluster
1
Cluster
2
I
have two 3900 gateways currently connected to cluster 2 that are configured for
as 500 software MTP's. That is all these gatways do now, nothing else.
I
would like to share these software MTP's with the other 2 call manager
cluster. I do not see a way to do this.
You
cannot share the same dspfarm. You can however create separate dspfarms
(subdividing the total capacity in the process) and separate call manager
groups which point to Cisco 3945 separate clusters.
2014年2月13日星期四
SPAN configuration on 3750
I'm trying to configure a mirror port on a WS-C3750X-48T-L . This configuration needs to replicate data from local ports, but I need that also act as a regular access port.
With the initial configuration, SPAN port, there is no problem, all the data of the configurated ports is replicating in the configurated port. On the port configurated as mirror there is a PC connected for audio recording. When the port is not operating as SPAN there is communications without problem over the LAN. But when I configure the port as SPAN, communication is interrupted.
Here is the actual configuration:
SWITCH1-PISO7#sh
monitor session 1
Session 1
Type : Local Session
Source
Ports :
Both :
Fa1/0/1-7,Fa1/0/9-12,Fa1/0/32-33,Fa1/0/35,Fa1/0/38
Destination
Ports : Fa1/0/47
Encapsulation : Native
Ingress :
Enabled, default VLAN = 215
Ingress encap : Untagged
SWITCH1-PISO7#sh
run int fa1/0/47
Building configuration...
Current configuration : 112 bytes
interface
FastEthernet1/0/47
switchport
access vlan 215
switchport
mode access
spanning-tree
portfast
end
SWITCH1-PISO7#sh
ver
Cisco IOS Software, C3750 Software (C3750-IPSERVICES-M), Version 12.2(50)SE1, RELEASE SOFTWARE (fc2)
****output omitted****
Switch Ports Model SW Version SW Image
* 1 52 WS-C3750V2-48PS 12.2(50)SE1 C3750-IPSERVICES-M
****output omitted****
beforehand
thanks for your help
For
the 3750 family, the span destination ingress forwarding capability's only purpose is to enable
ingress traffic forwarding of frames
received on the span destination port from an Intrusion Detection Systems (IDS) or comparable device. Like a
span destination port without ingress
forwarding, MAC address learning is disabled on a span destination port with ingress forwarding, and
a span destination port with ingress
forwarding does not transmit any traffic except that WS-C3750X-48T-S required for the SPAN session.
2013年12月11日星期三
Cisco 3560 switchport light stays orange when VLAN is applied.
![]() |
i have configured
the WS-C3560X-24P-L switch port to the VLAN I require, I am able to plug in a laptop and talk
on the network correctly (pull DHCP and get on the internet on the correct
network). But when I try plugging up my DSLAM the port stays orange. If I leave
the VLAN set to the default (vlan1) it will turn green but as soon as I change
the VLAN it turns orange again. The settings are the same on both DLSAMS as far
as port and VLAN configuration goes. The port is linking up correctly at 100
Full on both sides.
I will add more
information as I continue to troubleshoot this. But for now hopefully this
should give a brief explanation of my problem in case I am just overlooking
something very simple.
no cdp enable
spanning-tree bpdufilter enable
2013年11月25日星期一
Setup Port Channel on Cisco 3560
I
have 2 Layer3 switches. (Cisco WS-C3560X-24P-L). I am setting:
interface
FastEthernet0/1
channel-group 1 mode on
!
interface
FastEthernet0/2
channel-group 1 mode on
!
interface
FastEthernet0/3
channel-group 1 mode on
!
interface
FastEthernet0/4
channel-group 1 mode on
!
interface
Port-channel 1
no switchport
ip address 192.168.1.2 255.255.255.0
Other
switch is same but using 192.168.1.1 255.255.255.0
I
am getting connectivity. But Basically would like to have fail-over and load
balancing.
So
out of the 4 fast Ethernet ports. If one fails. There should still be
connectivity.
Get
rid of your IP addresses. Port bonding
is a layer 2 game and you don't need them.
Here
is an example of a working LACP etherchannel configuration on a WS-C3560G-24TS
running IPservices 12.2(50)SE4. The
config on the partner switch is identical.
port-channel
load-balance src-dst-mac
!
interface
Port-channel23
description ** LACP channel to SWITCH2, ports
23-24 **
switchport trunk encapsulation dot1q
switchport trunk native vlan 11
switchport trunk allowed vlan 2-499
switchport mode trunk
switchport nonegotiate
spanning-tree link-type point-to-point
!
interface
GigabitEthernet0/23
description ** SWITCH2 etherchannel port 1 **
switchport trunk encapsulation dot1q
switchport trunk native vlan 11
switchport trunk allowed vlan 2-499
switchport mode trunk
switchport nonegotiate
logging event status
channel-group 23 mode active
!
interface
GigabitEthernet0/24
description ** SWITCH2 WS-C3560V2-48PS-S etherchannel port 2 **
switchport trunk encapsulation dot1q
switchport trunk native vlan 11
switchport trunk allowed vlan 2-499
switchport mode trunk
switchport nonegotiate
logging event status
channel-group 23 mode active
2013年11月14日星期四
Cisco 3560 Switches Installing SFP Modules
Removing and installing an SFP module WS-C3560V2-48TS-S can
shorten its useful life. Do not remove and insert SFP
modules more often than is absolutely
necessary.
Step 1 Attach an ESD-preventive wrist strap
to your wrist and to a bare metal surface on the chassis.
Step 2 Find the send (TX) and receive (RX)
markings that identify the top side of the SFP module.
Note On some SFP modules, the send and
receive (TX and RX) markings might be replaced by arrows
that show the direction of the connection,
either send or receive (TX or RX).
Step 3 Align the SFP module in front of the
slot opening.
Step 4 Insert the SFP module into the slot
until you feel the connector on the module snap into place in the rear
of the slot.
Step 5 For fiber-optic SFP modules, remove
the dust plugs from the optical ports, and store them for later use.
Caution Do not remove the dust plugs from
the fiber-optic SFP module port or the rubber caps from the
fiber-optic cable until you are ready to
connect the cable. The plugs and caps protect the SFP module
ports and cables from contamination and
ambient light.
Step 6 Insert the cable connector into the
SFP module:
•
For fiber-optic SFP modules, insert the LC or MT-RJ cable connector into the
SFP module.
•
For copper SFP modules, insert the RJ-45 cable connector into the SFP module.
Note When connecting to 1000BASE-T SFP
modules, be sure to use a twisted four-pair, Category 5 cable.
For more Cisco WS-C3560X-24P-L information please click here
2013年11月13日星期三
3560 Showing Garbage in Console
Cisco WS-C3560X-48PF-S series products have two main
categories, Cisco 3560V2 and Cisco 3560X, 3560V2 is FE based switch while 3560X
is GE based switch, the previous Cisco 3560, 3560G and 3560E are end of sales
now and replaced by Cisco 3560V2 and Cisco 3560X. Cisco Catalyst 3560 v2 Series
consumes less power than its predecessors. The 3560-X Series Switches is an
enterprise-class lines of stackable and standalone switches.
I have few 8-port 3560's (WS-C3560-8PC)
that I have been using to roll out a Metro Ethernet upgrade. I have one switch that originally configured
just fine, but now it is displaying all kinds of gibberish in the console
window. I can telnet into the switch
ok. The configuration register on it is
set to 0xF. But I have tried using a
serial connection from multiple computers, and they all show the same
garbage. I have 4 of these switches next
to each other. They all have the same
IOS: 15.0(2)SE image. They all have the
same configuration register. I can
console into all of them except for this one switch.
I have verified my terminal settings, and
they are as suggested:
Speed: 9600 bps
Databits: 8
Parity bits: 0
Stop bit: 1
No flow control
This time, I have tried changing to all of
the following baud rates, and they all produce gibberish:
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
115200 bps
3Anetwork.com keeps regular stock of 3560V2
and 3560X switches. Among all Cisco Catalyst 3560 switches, WS-C3560V2-24TS-S,
WS-C3560V2-24PS-S WS-C3560X-24T-L, WS-C3560X-24T-S and WS-C3560X-24P-S are best
selling models. 3Anetwork.com offers best Cisco 3560 Price, Cisco 3560V2 Price,
Cisco 3560X Price, ship to worldwide.
For more Cisco WS-C3560X-48PF-L information please click
here
2013年11月6日星期三
Cisco Catalyst WS-C3750V2-48PS-S Switch
An ideal fit for midsized organizations and
enterprise branch offices, the Cisco WS-C3750V2-48PS-S eases deployment of
converged applications and adapts to changing business needs by providing
configuration flexibility and support for converged network patterns.
The Cisco Catalyst 3750V2-48PS switch not
only consumes far less power than most other Cisco switches, but it also helps
increase the overall productivity of your network for data, voice and video.
Supporting Cisco's EnergyWise technology, this switch from Cisco's Catalyst
3750 series gives you the opportunity to manage your power consumption, reduce
your overall energy costs and decrease the size of your carbon footprint.
48 x 10/100/1000 ports
Optional four Gigabit Ethernet (GbE) SFP or
two 10GbE SFP+ uplink network modules
Dual redundant, modular power supplies and
fans
Media Access Control Security (MACsec)
hardware-based encryption
IPv4 and IPv6 routing, Multicast routing,
advanced quality of service (QoS), and security features in hardware
Enhanced limited lifetime warranty (LLW) with
next business day (NBD) advance hardware replacement and 90 day access to Cisco
Technical Assistance Center (TAC) support
Enhanced Cisco EnergyWise for operational
cost optimization by measuring actual power consumption of the device,
reporting, and reducing energy consumption across the network
Cisco StackPower technology: An innovative
feature and industry first for sharing power among stack members
Cisco StackWise Plus technology for ease of
use and resiliency with 64 Gbps of throughput
For more Cisco WS-C3560X-24T-L information please click
here
订阅:
博文 (Atom)